Elegant Radiators
Heat Loss Report & Radiator Quote 20th February 2026
Ref: AH-FEB2026

Anower Hossein

Gretna Road, Coventry CV3 6DP

Property
End-of-Terrace (1952)
Walls
Solid Brick
Heating
Gas Combi
Flow Temp
70/50°C (ΔT50)
Type 22 Double Panel Convector Radiators
Based on your preference, I’ve matched Type 22 panel radiators to each room’s heat loss calculation. These are the highest-output standard panel type — double panel + double convector for maximum heat. All white finish, includes brackets & fixings.

Heat Loss Summary

Calculated per BS EN 12831 with 15% safety margin. End-of-terrace (1952): 3 external walls, solid brick U=2.1, double glazing U=1.4. Loft uninsulated U=2.3, suspended timber floor U=1.5.

Room Floor Area Target Heat Loss BTU/h
Living Room Ground 14.1 m² 21°C 2,114W 7,213
Dining Room Ground 13.3 m² 21°C 2,125W 7,251
Hallway Ground 5.4 m² 18°C 890W 3,037
Main Bedroom First 11.6 m² 18°C 1,831W 6,247
Bedroom 2 First 11.6 m² 18°C 1,831W 6,247
Upstairs Office First 6.0 m² 21°C 1,305W 4,453
TOTAL 62.0 m² 10,096W 34,448

Note: First floor rooms have uninsulated loft above (U=2.3) — significant roof heat loss. Larger radiator sizes recommended for bedrooms to compensate.

Living Room — Select Radiator

7,213 BTU/hr — 2,114W required
Ground floor, front
4.3 × 3.6m (14.1 m²)

Front wall with bay window (2.1×1.5m). Under-window placement ideal. Solid brick + suspended timber floor.

Dining Room — Select Radiator

7,251 BTU/hr — 2,125W required
Ground floor, rear
4.1 × 3.4m (13.3 m²)

No windows — 2 external walls (rear + side). Flexible radiator placement on any internal wall.

Hallway — Select Radiator

3,037 BTU/hr — 890W required
Ground floor, side passage
3.3 × 1.8m (5.4 m²) • 3.5m ceiling

Compact space with front door drafts (ACH 2.0). Tall 3.5m stairwell ceiling. Needs a compact radiator.

Main Bedroom — Select Radiator

6,247 BTU/hr — 1,831W required
First floor, front
4.1 × 2.8m (11.6 m²)

Corner room (2 external walls) with uninsulated loft above — 560W lost through roof alone. Under-window (1.9×1.3m) placement fits a 1200mm rad.

Bedroom 2 — Select Radiator

6,247 BTU/hr — 1,831W required
First floor, rear
4.1 × 2.8m (11.6 m²)

Mirror of main bedroom — same 2 external walls + uninsulated loft above. Under-window (1.9×1.3m) placement.

Upstairs Office — Select Radiator

4,453 BTU/hr — 1,305W required
First floor, side/rear
2.9 × 2.1m (6.0 m²)

Small room. 2 external walls + uninsulated loft above. Window (1.0×1.3m) — 800mm radiator fits under the sill.

Radiator Valves

TRV Angled Valves — 6 Pairs (1 per radiator) Included

TRV Valve
TRV Angled Valve with Lockshield

Thermostatic radiator valve — controls room temperature automatically
6 pairs needed (1 per radiator) • 15mm compression • Angled for wall pipes
White finish to match your radiators

6 × £25 = £150

Quote Summary

Living Room Flomasta 600×1400mm (8,165 BTU) £239
Dining Room Flomasta 700×1200mm (7,909 BTU) £199
Hallway Flomasta 600×600mm (3,499 BTU) £59
Main Bedroom Flomasta 600×1200mm (6,998 BTU) £99
Bedroom 2 Flomasta 600×1200mm (6,998 BTU) £99
Upstairs Office Flomasta 600×800mm (4,666 BTU) £79
TRV Valves 6 pairs × £25 £150
Products Total £924
10% Story Discount Before & After photo story −£92.40
+ 5% Photo Review Post photos + thank you to our page −£46.20
Total (inc. VAT) £785.40
Free UK delivery. All prices include VAT.
All radiators: White Type 22 Double Panel Convector.
TRV valves included — everything you need for the install.
UP TO15% OFF
Exclusive Discount Offer
10% Discount: If we can create a “Before & After” story of your project.
Extra 5% Refund: If you post your photos to our company page with a quick “thank you” for the service and your elegant new radiators!
Installation (includes FREE magnetic filter & system chemicals)
£500
Standard Swap
Replacing in existing locations
Approx. 2 days labour
£850
Full Relocation
Moving radiators to new walls, lifting floors & embedding pipes
Approx. 3 days labour
Pro Tip: Type 22 panel radiators have standard side connections, so if your current radiators are a similar height (600mm or 700mm), existing pipework can usually be reused — making installation quick and straightforward. A standard swap is often all you need.